Hi,

Just upgraded to new 328mega chip.

Running HAH 303/2.4

Had found some corruption in xap-livebox.ini file, all cleaned up now.

Reset all RF codes for my HE 302 devices to:

rf1.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B0
rf2.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B1
rf3.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B2
rf4.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B3
rf5.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B4
rf6.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B5
rf1.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B0
rf2.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B1
rf3.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B2
rf4.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B3
rf5.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B4
rf6.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B5

Now nothing works even though I have reset each device using group delete from remote.

Any ideas what I've done wrong?

Forums

I don't know if this will be useful to anyone else but I have for some time been interested in using the HAH to control my central heating boiler via a Drayton Digistat RF2 wireless boiler thermostat. I hope to be able to more closely control gas usage by doing so.
 
I posted a question about using URF to send the boiler on and off codes some time ago and Brett gave a tutorial on the procedure for encoding the pulses into the URF output. Unfortunately I could never get it to work and was uncertain whether I would be able to achieve what was required.
 
The problem, it turns out, was that I was not using the right code because the Digistat transmitters have different ID's and I had gleaned the code from a source on the internet. Not being the possessor of such a thing as an osilloscope I was at a loss as to how to find the codes from my own transmitter. The solution which I reached was to buy a cheap 433 mhz receiver which I linked to an audio cable with a couple of 10k resistors in the lines. I was then able to grab the output of the receiver using the audio manipulation software "Audacity" (available as a free download) by connecting the audio cable to the line-in socket of my computer. The RF bursts are then able to be viewed as "osilloscope-like" traces and the pulse lengths measured for translation into the URF helper.
 
Happily by following Brett's tutorial I now have my central heating boiler under the control of the HAH using a simple lua script to sample temperatures and send the appropriate signals to the boiler. Another triumph for the HAH! 
 
If anyone is interested I can post the Digistat codes (bearing in mind that the may be different on your system) and the lua script (which is fairly simple).

Unfortunately due to a massive C*ck up by my telephone provider I have been without phone or broadband for a couple of weeks now. It's not looking good for an early resolution Grrrrrrrrrrrr!  

Forums

Hi All -

I've just been given a load of these (Byron RS3 3000W power switch) - I think they're HomeEasy, but the old type with the pinwheel selector (choices are A-1, A-2, A-3 then B-1,B-2 etc to D-3).... are they compatible with the HAH Rf and can you point me at the relevant codes (I've looked in the wiki but there's no mention of Byron stuff and the HomEasy is for the learning modules!!).

Looking forward to being able to turn the kettle on from up in the office!!!!

EJ

Forums

My HAH was doing this every so often and a reboot did not help a full power off/on had to be done.

 

Today nothing i did got the HAH working until i unplugged and replugged in the HAH psu.

 

I have now replaced the psu with an uprated one so hopefully that should help.

Forums

Hi,

 

I picked up some of the normal mains socket Status RF modules the other day (working fine), but also caught sight of a 4 way extension block with individual control of the sockets!

Thought it looked useful so grabbed one, problem is it seems to use a slightly different protocol to the individual sockets :( When you train it with the remote, you have to press the learn button on the extension block, and any button on the RF remote. After this all 4 on/off sections work correctly without further training, which suggests to me that the training procedure just sends a unique code from the transmitter?

Anyone seen/bought/played with one of these yet? :D

 

Andy

Forums

Hi Brett,

I used to be able to select multiple RF items from the GUI and toggle them on/off and they would all switch as desired, however now only the first item in the list gets switched - I only noticed this after updating to the Mega328 and the Universal RF system.

David

Forums

Hello! 

I have a new Livebox / HAH and am working my way through a series of problems, one of which being the RF functionality, another being the LCD output. I realised the other day that i was being a bit of an idiot and was following the instructions to the letter! I plugged it in for the first time and the LCD didn't work. I then went on to get annoyed at why the RF wasn't working only to later realise that i hadn't plugged it in yet... because that instructions hadn't told me to!

Anyway, i'm still trying to fix the LCD issues but decided to crack on with the RF functionality. I turned off the livebox and plugged it in and turned it back on. I didn't notice any different ( and still tring to get my Home Easy 330v2's to work ) when i noticed that the normal HomeEasy remote didn't work. What was more strange was that my Current Cost meter was also not getting a signal. The only conclusion i could come to was that by plugging in the RF unit to the HAH it was interfering with the others so i took it out! Sure enough, as soon as i booted it back up both the remotes and the CC128 worked again!

This seems rather odd given that i can't be the first one that uses Current Cost and the RF unit. Any ideas?

Andy. 

Forums

Hi,

I've just upgraded my HAH with the 328 chip and will soon be approaching (and exceeding - pending a raised limit) the arbitary limit of 32 defined RF devices on the GUI - I think Brett mentioned in a previous post that this could be changed if anyone made the request - please Brett can this be increased if this has not already happened in one of the many recent updates?

Could I also request the facility to re-order the list of devices without having to cut and paste, having added several new devices in a couple of rooms and wanting to keep all devices per room together in the list it was quite an operation to cut and paste the entries into their new locations - although I did see that you have put together a new GUI tab in release 299 which could well address my problem and then some - so many excellent improvements/developments I'm having problems keeping up - keep up the excellent work.

Thanks

David

Hello,

Has anyone tried the HE330v2 sockets? I've got a three pack of the sockets. All appear to work fine - but only on one code...i.e. I can program them all to one code but no more...i've tried changing the last hex digit as per other posts and the Wiki, however nothing other that '0' as the last digit will work...

 

[rf]
# v1. Up to 12 RF units may be defined.
# v2. Up to 96 RF units may be defined.
devices=4
rf1.off=01020320028A05DC028A05DC0514032004B00C029C4015CB1555555540 < -- Lidl socket from HAH shop - working OK
rf1.on=01020320028A05DC028A05DC0514032004B00C029C4015CB1555561600
rf2.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B0 < -- This code appears to work ok
rf2.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B0
rf3.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B2 < -- Will not work..
rf3.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B2
rf4.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B4 < -- Will not work..
rf4.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B4
rf1.label=RF 1
rf2.label=RF 2
rf3.label=RF 3
rf4.label=RF 4

 

Forums

I know there crap but i have 12 of the buggers (wife keeps buying them)

does anyone know the code? i hvae read the wiki but am unable to get a string that works, anyone got a string working?

 

and which bit do you change for the data burst?