JeeNodes

Description

Issues around HAHNode and JeeNodes

Forums

Can someone tell me what sort of distances I can have between the basenode and room node.

 

I have will have my basenode in the loft and would like to know if it will reach my lounge?

Forums
Today ‘out of the blue’ the temperature sensor from my RoomNode switched from Positive to Negative values please see the attached 2 screen shots, I’ve tried removing the batteries from the RoomNode to see if this might reset it, it hasn’t so far. Can anyone help/advise?
Forums

need to add about 20degrees onto a temp sensor due to inability to locate it exactly where i want too (place i put it reads apx 20degrees lower)?

 

excerpt from script here:--

 

local jeemon={
      port="/dev/ttyUSB0",
      baud=57600,
      stop=1,
      databits=8,
      parity="none",
      flow="none"
}

-- Keyed by NODE ID
local nodes = {
   [2] = RoomNode{base="dbzoo.livebox.jeenode:pond", endpoints={light=1,temp=1,lobat=1}, ttl=1800},
}

function init()
   monitor(jeemon, nodes)
end

Forums

Well i have just spent 2 hours trying to reconfig a roomnode id.

 

my hah simply will not talk to the basenode in programming mode.

yes assists are disabled and cc and i have dissconnected hub.

 

now i am not a programmer but i do have a stk500 and the other bit Derek sells in the shop-bought so i could "copy" chips-which i have done many times for others.

 

what software do i need to be able to get to the ship and alter the node id. i tried with avr studio 4 but it really is unfriendly!

 

anyone advise?

 

Dean

Forums

I thought I would post this and see if anybody has any ideas. I have followed a few good sites on decoding the Conrad FHT8V radiator valve system, the idea is to intrograte control of the valves into XAP. A friend and I are trying to control a number of valves and I initially looked at using a HAH Central node modified for 868Mhz OOK. It soon became apparent that it may be troublesum having to sync up a number of valves to one central node and so we decided to look at intergrating the control into the roomnodes instead. We are intending to have one roomnode per valve / room where control is needed and have successfully produced a roomnode that still sends the data back to HAH central as usual, but also sends OOK signals to the valve, It is working well so far, but the problem is that of current drawn from the batteries of the modified airwick, due to timing inaccuracy's associated with sleep mode, I have had to remove the sleep function from the roomnode sketch. The problem is the valve only wakes up about every two minuites to recieve data and due to the timing issues the valve soon dropped out of sync. I am thinking mabe adding a real time clock to handle the timing and wondered if any one has any further ideas. For now we may temporary power the roomnodes with small mains adapter and move on, but it would be nice to get the portability of the roomnodes back at some stage.

 

Ian Blackman (G4OCQ)

Forums

Does anyone else see regular dropouts like these?

https://cosm.com/feeds/71076

1 and 2 are on the same node

3 and 4 are currently disconnected so ignore those traces

5, 6 and 7 are on the same node

I did have an issue at first with dropouts on all nodes but that turned out to be a flaky HAHcentrol node

Forums

This is modified roomnode source. The 'moved' signal no longer sends an immediate transmission but each 'moved' pulse is counted. The total count is sent where the 'humi' value would be, every 5 minutes. The count is retained until an 'ack' is recieved from the basenode.

The code has been working well now for a couple of weeks and now the heating season will soon be upon us, I thought others may want to try.

If you edit the jeenodeApplet.lua as follows...

  [yourRoomnodeNumber] = RoomNode{base="dbzoo.livebox.jeenode:gas-monitor", endpoints = {temp=1,lobat=1,light=1,moved=1,humi="count"}, ttl=900},

you will get the count endpoint at dbzoo.livebox.jeenode:gas-monitor.count every 5 minutes

If you are like me and you gas box is outside you also get a handy monitor of the outside temperature and light level :)

Forums

Well, after trying about everything I can think off I have decied I need help....

 

My daughter soldered up the 2 nodes a few weeks ago (she was bored in the school hols & not a bad hand with a soldering iron !) and I eventually got round to loading the scripts which went ok.

 

I have just picked them up again to get them working and built the room node into the airwick.

 

But no data is being picked up !

 

I seem to have a problem in that doing any fault finding I can only occationally connect to the basenode via microcom once I have rebooted the HAH a few times, I do though get back '[HAHCentral.1] D i1 g212 @ 868 MHz'  but nothing else.

 

Any guidance greatly appreciated......

Forums

Hi All....

Just getting to grips with the HAHNode stuff..... I've got it to a stage where I can see the temp and light endpoints (from the jeenodeApplet.lua) with good data (and lots of spurious stuff) in the Serial view.....however, after about 15-20 mins the good data stops (but the ? spurious stuff continues on the Serial line)....

If I power off the remote node, then power it on again I immediately get good data - but again only for 15-20 mins..... if I try the power cycle again I get no good data at all.  I then have to re-boot the Hub and all starts from the top again....

Do you think I've missed something, or is it a hardware thing?

Hope you can help....

EJ

Forums

Got my second hahnode working - I thought I would connect it to the hot water tank.

It works however I get a flip from +51degrees to -51 degrees as you can see from the 

24 hour track on https://cosm.com/feeds/13194?pachube_redirect=true

Feed number 6

The DS18B20 datasheet says it does -50 to plus 125 degrees celsius.

But the roomnode.lua refers to -50 to +50 so presumably I am going out of range.

I can also see in the change log the following:

 

Allow HAHnodes a temperature offset like
r376.  It does this with toff and toff2 as
part of the HAHnode endpoint
configuartion.  Wiki will need updating
after this has been released.


 So is the solution to put a toff entry somewhere (livebox.ini) to at least get the graph looking right
and then try and find a way to change the -50/+50 range to -20/+80 or somesuch?

Ideas in aid of my crude programming skills much appreciated.

Regards

Kim