The EDF EcoManager normaly comes with 3 plugin IAMS (Individual Appliance Monitors). It is capable of supporting upto 14 IAMs and a whole house transmitter
These EDF IAMs are not the same as Currentcost IAMS in that the EDF ones have a control capability.
The CC IAMS are not compatible with EcoManager.
The EDF IAMS are not compatible with CC units
The CC Optismart, development boards ( analog and digital), and the mini/clamp transmitters and whole house transmitters are not compatible with the EDF IAM channels
It is possible to use an EDF or CC "Whole house" transmitter on either CC or Ecomanager but only as the whole house transmitter
I do not believe that the ecomanager supports the use of more than one clamp on the whole house transmitter
The HAH supports any one of the Ecomanager, both CC classic units, the Current Cost CC128 and Envi, and for the CC128 and Envi you can also have upto 9 channels which can be any combination of CC IAMS's, Optismart, development boards ( analog and digital), and the mini/clamp transmitters and whole house transmitters.
When configured for EDF, the HAH supports the Ecomanager with a single whole house transmitter and upto 14 ecomanager IAM's. The On/Off Switching capability of the EDF IAM's is not yet supported by the HAH.
Thanks Kevin you saved me from wasting my money on an Eco Manager the other day as I had wanted to use 2 clamps one for PV and the other for whole house consumption.
Member for
15 years 10 monthsthe forums are your friend
Yes and only the whole house.
no good for solar PV
search forums and you will see a discussion ref edf ecomanager
Member for
14 years 7 monthsOK thanks
OK thanks
Member for
16 years 5 monthsFor those that come after...
The current position May 2012 is as follows
The EDF EcoManager normaly comes with 3 plugin IAMS (Individual Appliance Monitors). It is capable of supporting upto 14 IAMs and a whole house transmitter
These EDF IAMs are not the same as Currentcost IAMS in that the EDF ones have a control capability.
The CC IAMS are not compatible with EcoManager.
The EDF IAMS are not compatible with CC units
The CC Optismart, development boards ( analog and digital), and the mini/clamp transmitters and whole house transmitters are not compatible with the EDF IAM channels
It is possible to use an EDF or CC "Whole house" transmitter on either CC or Ecomanager but only as the whole house transmitter
I do not believe that the ecomanager supports the use of more than one clamp on the whole house transmitter
The HAH supports any one of the Ecomanager, both CC classic units, the Current Cost CC128 and Envi, and for the CC128 and Envi you can also have upto 9 channels which can be any combination of CC IAMS's, Optismart, development boards ( analog and digital), and the mini/clamp transmitters and whole house transmitters.
When configured for EDF, the HAH supports the Ecomanager with a single whole house transmitter and upto 14 ecomanager IAM's. The On/Off Switching capability of the EDF IAM's is not yet supported by the HAH.
HTH ( let me know if I have not made it clear)
kevinT
Member for
14 years 7 monthsThanks Kevin you saved me
Thanks Kevin you saved me from wasting my money on an Eco Manager the other day as I had wanted to use 2 clamps one for PV and the other for whole house consumption.
Member for
15 years 10 monthshuh?
I did say in my original post very clearly no good for solar pv :)